Installation Procedure

Adherence to the following will aid in problem-free installation with long-term reliability:

Installation Precautions - Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be connected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated equipment may be damaged by removing and/or inserting cards, modules, or interconnecting cables while the unit is energized. Do not attempt to install, service, or operate this unit until manuals are read and understood. CAUTION - System Re-acceptance Test after Software Changes: To ensure proper system operation, this product must be tested in accordance with NFPA 72 after any programming operation or change in site-specific software. Re-acceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. This system meets NFPA requirements for operation within the range of 0°C-49°C (32°F-120°F) or humidity within the range of 10%-93% at 30°C (86°F) noncondensing. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27º C/60-80º F. Verify that wire sizes are adequate for all initiating and indicating device loops. Most devices cannot tolerate more than a 10% I.R. drop from the specified device voltage. Like all solid state electronic devices, this system may operate erratically or can be damaged when subjected to lightning induced transients. Although no system is completely immune from lightning transients and interference, proper grounding will reduce susceptibility. Overhead or outside aerial wiring is not recommended, due to an increased susceptibility to nearby lightning strikes. Consult with the Technical Services Department if any problems are anticipated or encountered. Disconnect AC power and batteries prior to removing or inserting circuit boards. Failure to do so can damage circuits. Remove all electronic assemblies prior to any drilling, filing, reaming, or punching of the enclosure. When possible, make all cable entries from the sides or rear. Before making modifications, verify that they will not interfere with battery, transformer, or printed circuit board location. Do not tighten screw terminals more than 9 in-lbs. Over-tightening may damage threads, resulting in reduced terminal contact pressure and difficulty with screw terminal removal. Silent Knight fire alarm control panels contain static-sensitive components. Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. Use static suppressive packaging to protect electronic assemblies removed from the unit.

Follow the instructions in the installation, operating, and programming manuals. These instructions must be followed to avoid damage to the control panel and associated equipment.

Page 3
Image 3
Honeywell 5820XL manual Installation Procedure

5820XL specifications

The Honeywell 5820XL is a versatile and advanced wireless motion detector designed for residential and commercial security applications. It offers a combination of cutting-edge technology and user-friendly features, making it an ideal choice for ensuring safety and peace of mind.

One of the standout features of the Honeywell 5820XL is its advanced imaging technology. The detector employs Passive Infrared (PIR) sensing, which allows it to detect motion based on the heat emitted by objects in its field of view. This ensures high sensitivity to human movement while minimizing false alarms triggered by pets or environmental factors.

The Honeywell 5820XL is engineered with a sleek, low-profile design that can seamlessly blend into various indoor environments. Its unobtrusive presence makes it suitable for both residential homes and businesses. The device is also lightweight and compact, facilitating easy installation in various locations without compromising performance.

Another key characteristic of the 5820XL is its impressive range of detection. The unit offers a coverage area of up to 40 feet in a standard installation, ensuring a wide detection span that is effective in larger spaces. Additionally, it features a 90-degree field of view, allowing for comprehensive monitoring of hallways, rooms, and open areas.

The 5820XL is built with dual zone detection technology, which helps it distinguish between different types of motion. This not only reduces false alarms but also provides enhanced security by focusing on genuine threats. Furthermore, the detector is equipped with a tamper switch that triggers an alert if the unit is removed or tampered with, providing an additional layer of protection.

For added convenience, the Honeywell 5820XL utilizes a robust wireless communication system, ensuring a reliable connection with Honeywell security panels. The unit operates on a long-lasting battery, which minimizes maintenance and allows for uninterrupted performance.

In summary, the Honeywell 5820XL wireless motion detector combines advanced sensing technology, expansive detection range, and a sleek design to provide effective motion surveillance. Its dual zone detection, along with the tamper alert feature, adds to its functionality, making it a valuable addition to any security system. Whether for residential or commercial use, the Honeywell 5820XL stands out as a dependable choice in motion detection technology.