5.2List of Hochiki SLC Devices

The following Hochiki SLC devices can be used with the control panel. See the appropriate section number in this manual or the device installation instructions (packaged with the device) for more information.

Note: The control panel supports the use of either Hochiki SLC devices or SK SLC devices. You cannot install both SLC device types on this control panel.

 

 

Section No./

Model Number

Model Name/Description

Installation

 

 

Instructions PN

 

 

 

 

 

 

SD505-APS

Photoelectric smoke detector.

 

SD505-AIS

Ionization smoke detector

Section 5.7

 

 

 

SD505-AHS

Absolute temperature heat detector. Trip point range from 135°F–150°F (0°C–37°C).

 

 

 

 

SD505-6AB

6" base for use with the SD505-AHS, SD505-AIS, and SD505-APS.

150955

 

 

 

SD505-6IB

6" short circuit isolator base for use with the SD505-AHS, SD505-AIS, and SD505-APS

151175

 

 

 

SD505-6RB

6" relay base for use with the SD505-AHS, SD505-AIS, and SD505-APS

151192

 

 

 

SD505-6SB

6" sounder base for use with the SD505-AHS, SD505-AIS, and

151191

 

SD505-APS SLC devices

 

 

 

 

SD505-DUCT

Duct Smoke Detector. Duct Housing including the SD505-APS Analog Photoelectric Smoke

1700-09882

 

Sensor. Intake tubing for duct available in three lengths:

 

 

SD505-T2.5 (2.5 foot); SD505-T5 (5 foot); SD505-T10 (10 foot)

 

 

 

 

SD505-DUCTR

Duct Detector housing with relay base. Duct housing with relay base including SD505-APS

1700-09882

 

Analog Photoelectric Smoke detector pre-installed

 

 

 

 

SD505-ADH

Duct Detector Housing for use with the SD505-AIS or SD505-APS smoke detectors. Intake

151040

 

tubing for duct available in three lengths:

 

 

STS-2.5: Duct widths 1.0’ to 2.5’; STS-5.0: Duct widths 2.5’ to 5.0’; STS-10.0: Duct widths

 

 

5.0’ to 10.0’ When ordering SD505-ADH, specify intake tubing size and order the appropriate

 

 

smoke detector (if needed).

 

 

 

 

SD505-ADHR

Duct detector housing with relay (for use with SD505-AIS or SD505-APS smoke detectors)

151126

 

 

 

SD500-PS/-PSDA

Single or dual action addressable pull station

151177

 

 

 

SD500-AIM

Addressable input module (switch input), standard size, dipswitch configurable

151071

 

 

 

SD500-MIM

Mini input monitor module (switch input), small size, dipswitch configurable. Fits in single-

151071

 

gang box with manual pull station switch.

 

 

 

 

 

SD500-ANM

Addressable notification module

151109

 

 

 

SD500ARM

Addressable relay module dipswitch configurable.

151091

 

 

 

SD500-SDM

Addressable smoke detector module. Use to assign an address to a loop of conventional

151193

 

devices.

 

 

 

 

SD500-LIM

Line isolator module. Fits in a double gang box.

151125

 

 

 

SD500-LED

Addressable LED driver module. Capable of driving up to 80 LEDs. Up to 40 SD500-LED

151232

 

Driver Modules can be used per SLC loop.

 

 

 

 

SD505-DTS, SD505-DTS-K

Remote test switch & LED indicator for the SD505-ADHR and SD505-DUCTR

151126

 

 

 