Programming

disabled by default. For 5211 installation, see Section 4.12.

Note: Ground start cannot be used in UL installations.

12.Select Y (ground start used monitor line) or N (ground start not used don’t monitor line)

by pressing the or arrow, then press .

7.7.2.7 Answering Machine Bypass

This option is used in conjunction with the 5660 SKSS. This feature ensures that an answering machine will not interfere with communication between the panel and the computer. If an answering machine is used at the panel site, enable this feature; if an answering machine is not used, disable the feature.

This option is factory-programmed as Yes (enabled).

The selection made here must match the programming for this option in the Communication Configuration dialog box of the 5660 SKSS. See the 5660 SKSS manual for more information (PN 151240).

13.Select Y (answering machine bypass enabled) or N (answering machine bypass disabled)

by pressing the or arrow, then press .

7.7.3Sys. Event Outputs

1.Enter the installer code.

2.Press or to display the main menu.

3.Select 7 for Program Menu.

Display reads:

Initializing

 

Please wait . . .

4.From the Program Menu, select 5 for System Options.

5.From the System Options Menu, select 2 for Sys. Event Outputs.

151209

7-35