7. Rotate the blue side of the pickup roller until it clicks into place.

8. Replace Tray 2.

9.Turn the printer on. After a short time, the printer control panel might display the message NEW FUSER KIT.

10.If the message NEW FUSER KIT appears, go to step 11. If the message does not appear, you must reset the fuser count. See To reset the fuser count.

11.On the printer control panel, press to highlight YES, and then press to select it. The fuser count is reset and the printer is ready to use.

To reset the fuser count

1.Press MENU to enter the MENUS.

2.Press to highlight CONFIGURE DEVICE.

3.Press to select CONFIGURE DEVICE.

4.Press to highlight RESETS.

5.Press to select RESETS.

6.Press to highlight RESET SUPPLIES.

7.Press to select RESET SUPPLIES.

8.Press to highlight NEW FUSER KIT.

9.Press to select NEW FUSER KIT.

ENWW

Replacing supplies and parts 125