Security Features
The PSA has a front panel password to prevent unauthorized front panel configuration. It also has a web administrator name and password, which are required to configure the device or manage printers (the default user name is admin and the default password is admin). Additional web administrator accounts can be added.
The existing user account information of the NT 4.0 domain (name and password) is used; users or groups of users can be authorized to print through the PSA without requiring the creation of user accounts and passwords on the PSA.
For NT Domain networks, administrators can easily restrict print administration and services to specific groups or users. Valid access levels are:
●Print (print, pause, and delete your own print jobs)
●Manage Documents (print, pause, and delete other user's print jobs)
●Full Control (print, pause, and delete other user's print jobs; delete printers; and change security settings using native NT tools)
●No Access
Physical Specifications
Attribute | Specification |
Dimensions | 441 millimeters (mm) (17.4 inches) W x 323 mm (12.7 inches) D x 63 mm (2.5 |
| inches) H |
Weight | 4.6 kilograms (10.1 pounds) |
Temperature | Operating: +5 degrees Celsius (C) to +40 degrees C (41 degrees Fahrenheit (F) |
| to 104 degrees F) |
| |
Network connection | |
Serial port | |
| cable (APC part # |
Acoustic noise | 52 dB |
Minimum Hard Drive | 10 Gigabytes |
Minimum Processor Speed | 300 Megahertz |
Recommended Number of Printers | 50 |
Supported |
|
Largest Spoolable File Size | 2 Gigabytes |