Security Problems
If the PSA is joined to a domain, the domain password for the domain controller is included in the backup file. When that PSA backup file is restored, it might be necessary to join the PSA to that domain again because the password
might have changed since the backup file was created.
About the Indicator Lights (LEDs)
There are four indicator lights (LEDs) on the front of the PSA.
LED Normal Conditions
LED | LED Name Description |
Power LED ON when power is supplied to the PSA and it is turned on.
Network | LIT when there is a connection between the PSA and other |
Activity | network devices. |
LED | BLINKS when there is network activity between the PSA and |
| other network devices. |
Disk | ON when there is disk activity on the PSA. |
Activity |
|
LED |
|
Alert LED | OFF during normal operations (ON during bootup and shutdown). |
LED Problem Conditions
Condition | Possible Cause/Solution |
Power LED is not lit. | Power failure. Restore AC power. Bad power cord or power cord |
| unplugged. Verify and replace cord. |
Network LED never | Network connection is bad. Verify network cable connections, replace |
blinks. | cable. |
Alert LED remains | Critical failure is detected. Note the message on LCD front panel. |
lit after bootup is | Power cycle the unit. If the problem persists, contact HP support. |
completed. |
|