Formatter System
The formatter is responsible for the following:
•Receiving and processing ASCII data from printer interfaces.
•Monitoring front panel input and relaying printer status information (through the front panel and
•Developing/coordinating data placement and timing with the print engine.
•Storing font information.
•Communicating with the host computer.
The Formatter PCA can be divided into three functional areas:
•I/O Control
•Memory/Memory Management
•Data Processing
Formatter Feature | LaserJet 4 | LaserJet 4+ | LaserJet 5 |
Processor | 20 MHz 80960KA | 25 MHz 80960KB | 33 MHz 80960JF |
REt | Yes | Yes | Yes |
MEt | No | Yes | Yes |
Economode | No | Yes | Yes |
Configurable I/O Buffer Size | No | Yes | Yes |
Personality Resource | No | Yes | Yes |
Saving |
|
|
|
PowerSave Mode | No | Yes | Yes |
Font Cartridge Slot | Yes | Yes | No |
MIO Interface Level | 5.0 | 5.1 | 6.0 |
Serial Ports | |||
Parallel Port | Bitronics | ||
Maximum RAM (PCL/PS) | 34/22 MB | 66/50 MB | 66/52 MB |
SIMM Support | RAM/ROM | RAM/ROM | RAM/ROM/Flash |
PCL Level | 5 | 5E | 6 |
35 Intellifont/10 TT | 35 Intellifont/10 TT | 45 TT & Dark Courier | |
| Line Printer | Line Printer | Line Printer |
Default Symbol Set | |||
Paper Size Support | Letter/Legal/A4/Exec | Letter/Legal/A4/Exec | Letter/Legal/A4/Exec/A5 |
MP (Tray 1) Modes | First, Manual, Cassette | First, Manual, Cassette | First, Cassette |
Grayscale Hardware Assist | No | No | Yes |
ROPS 3 Hardware Assist | No | No | Yes |
Intuitive Control Panel | No | No | Yes |
|
|
|
|
I/O Control
The formatter I/O control is responsible for maintaining communications with the host system(s). The printer has three interfaces; serial, parallel (bitronic), and Modular I/O (MIO). The formatter maintains connections with hosts connected to these I/O’s including accepting data handshaking, and returning status.