Removing the Holding Tray Belt

Figure A-20 Holding Tray Belt Cover Plate

1 Remove all the screws securing the plate (see Figure A-20, callout 1).

2 Remove (1) E-clip shown in Figure A-20, callout 2.

3 Remove the bushing underneath the E-clip.

4 Release (2) latch points shown in Figure A-20, callout 3.

N o t e : The (2) washers on the gear beside the bushing are now loose. Remove and set aside.

5 Release the wires from the wire holder, allowing the cover to move aside to access the gears.

(continued on next page)

A -24 Duplexer