Voltage Test Points
The operating voltages of the printer can be verified by:
1 Listening for the exhaust fan. A rotating fan indicates that the +5 VDC and +24A VDC voltages are present. (The fan runs on +24A VDC. The +5 VDC enables the +24A VDC.)
2 Listen for the Main Motor. If the Main Motor runs, the +24B VDC is enabled, therefore +24A VDC must be present.
Measuring the DC Voltage Levels
The DC voltage levels can be measured directly on the DC Controller TB 201. TB 201 connects the DC Controller with the Power Supply. (See the Main Wiring Diagram, and Figure
Table | TB 201Voltages |
| |
|
|
|
|
Voltage |
| Color | Pin Number |
|
|
|
|
+5 VDC |
| Brown | 1, 2 |
|
|
|
|
+24 VDC |
| Red | 3 |
|
|
|
|
Ground |
| Blue | 4, 5, 6 |
|
|
|
|
|
|
|
|
|
|
|
|
Figure
Troubleshooting