Table | Repetitive Defects | |
|
|
|
Possible Cause | Action | |
|
| |
Toner Cartridge. The circumference of | Replace the Toner Cartridge. | |
the photoconductive drum is 3.75 inches |
| |
(94mm). The circumference of the |
| |
developer roller is 2 inches (51mm). If a |
| |
defect appears in the print image at |
| |
these intervals, assume the defect is |
| |
associated with the Toner Cartridge. |
| |
|
| |
Fuser Assembly. The Fuser Roller’s | Clean the Fuser Assembly rollers. | |
circumference is approximately | Replace the assembly if necessary. | |
2.5 inches (63mm) for the LJ4, and |
| |
(79mm) for the LJ4+/5. If a defect |
| |
appears at this interval, assume the |
| |
defect is associated with the Fuser |
| |
Assembly. |
|
|
|
| |
Dirty Roller. Any dirty roller along the | Examine and clean rollers along the | |
paper path may result in a pattern of | paper path. | |
repetitive print image defects. |
| |
|
|
|
For further information on interval dimensions, refer to the Repetitive Defect Ruler, Figure