Replacing the High Voltage Contact
Assembly/Feed Guide Assembly
The Toner Cartridge Guide Plate and the High Voltage Contact Assembly/Feed Guide Assembly must be installed together. Allow plenty of time to perform this procedure because several iterations of the process may be necessary.
1 Set the contact assembly over its mounting holes.
2 Slide the Toner Cartridge Guide Plate into position on a diagonal line (see Figure
3 Working the two parts together, lift the rear of the HVCP to provide enough clearance to install the Guide Plate.
4 When the Guide Plate is in position, press it into place on the sheet metal.
5 Press the HVCP into its mounting slots.
6 Install the Laser Shutter Pivot Pin and test the Laser Shutter for free operation.
7 Replace the gear cover (see Figure
Figure