3. Ensure the Operator Fibre Channel address menu is set correctly.See
options 4 and 5 in Table3 on page 10. Use the Fibre address
information to verify that:
vThe drive is receiving light over the Fibre cable (the address is not -- --
--)
vThe drive can communicate over the Fibre cable (address is not ?? ??
??)
vThe drive AL_PAis not already being used on the Fibre loop (address =
aa bb cc CONFLICT)
vThe drive AL_PAis not bypassed on the loop (address = aa bb cc
OFFLINE). This can be initiated by another device on the loop.
4. Check the Fibre Channel Attachment in its environments.
vIn an AIX environment, see AIX EnvironmentAttachment Checkon
page105.
vIn a SUN environment, see Sun Environment Attachment Checkon
page108.
vIn a Windows NT environment, see WindowsNT and Windows 2000
Environment Attachment Checkon page 109.
5. Verifysoftware levels and topology. Refer to IBM TotalStorage 3590 Tape
Subsystem Introduction and Planning Guide. Verifythat the desired topology
is supported.
6. If the problem remains, call the appropriate host, SAN, or drive service
organization, or refer to the host or SAN documentation.
110 3590 Operator Guide