Note: Use care to ensure that the tape is centered over the leader block. When the tape is centered over the leader block, there will be a 1.9

mm(0.075 inch) gap on both sides of the leader block. See Figure 23 on page 93.

Failure to properly center the leader block on the tape will cause the repaired cartridge to fail.

7. Carefully close the insert guide , and then place the insert pin into the opening of the guide.

 

Note: Use care to ensure that the insert pin is centered over the tape and

8.

the leader block.

 

 

 

Close the insertion lever

until it touches the insert pin.

9.

Push on the handle of the insertion lever

to force the insert pin and

 

the tape into the leader block.

 

 

 

Note: Push down on the handle smoothly and keep the force centered on

10.

the middle of the insert pin.

 

 

Open the insertion lever

and the insert guide

.

11.Remove the leader block from the attachment tool.

12.Inspect the leader block for correct insertion of the insert and alignment of the tape. See “Leader Block Inspection” on page 93. If the tape and insert are not correctly aligned, go back to step 4 on page 91 and repeat the procedure.

13.Use the clutch tool to wind the tape back into the cartridge.

14.Put the leader block in the cartridge.

15. Using the clutch tool

, carefully turn the tape reel to tension the tape

inside the cartridge.

 

16.Remove the clutch tool.

923590 Operator Guide

Page 112
Image 112
IBM manual 92 3590 Operator Guide