mount portion of the demount/mount message is displayed. For a loaded cartridge, the demount portion of the message is deleted when the accessor removes a cartridge from the loader.
A message control of “100” (alternate message) will cause the demount and mount messages to alternate as long as a cartridge is loaded. Demount is deleted when a cartridge is unloaded.
Routine Messages—General (Custom):
vCreation: A General message is created when a Display Message is received that requests a General message. A General message received while an earlier General message exists replaces the first General message.
vDisplayed: A General message displays when it is created.
vDeletion: When the device activity changes, or the Enter key is pressed, or when any other Routine Message enters a display mode a General message is deleted.
Routine Messages—Clean:
vCreation: When the device microcode detects that the device needs cleaning, it creates a Clean message. This is checked at every unload. When a diagnostic routine detects the need for cleaning, it may also create a Clean message.
vStored: When created, a Clean message is stored. When the Enter button is pressed, a displayed Clean message is stored. It is overlaid by another stored message, or if no other intervention message is present, by the Options/Status screen.
vDisplayed: When the device is unloaded, a Clean message is displayed.
vDeletion: When the device is loaded, a Clean message is deleted. This occurs regardless of whether the cartridge loaded was a data cartridge or a cleaner cartridge. When the
Combination Rules for Routine Messages: When any message enters display mode, it is combined with any other messages that already may be displayed in a sequence of messages.
In most cases, the message sequence will not grow beyond 2 or 3 alternating messages. It can grow to a 4- or