Table5. Operator Messages (continued)
Message Operator Response
FEED OVERCURRENT Service representative intervention required.
Report any FID codes to your service representative.
FSC TRAP TAKEN Service representativeintervention required.
HEAD CALIB FAILED.
Operator intervention or possible service representativecorrective
action required.
Select Unload on the operator panel and press Enter.If the device fails
to unload the cartridge, note any FID messages and call your service
representative.
INVALIDCARTRIDGE
Operator action required.
An invalid media type is detected. The invalid media must be replaced
with either a 3590 High Performance Cartridge Tapeor a 3590
Extended High Performance Cartridge Tape.An Extended High
Performance Cartridge Tapewill cause an invalid cartridge message if
it is loaded into a drive that is not Extended High Performance
Cartridge Tapecapable.
LOAD ERROR
Operator intervention or possible service representativecorrective
action required.
Select Unload on the operator panel and press Enter.If the device fails
to unload the cartridge, note any FID messages and call your service
representative.
1. Ensure that the cartridge is not brokenand the leader block is
intact. See Damaged Cartridgeson page87 and Leader Block
Replacementon page 90.
2. Ensure that the cartridge is a 3590 compatible-type cartridge.Also,
check the location of the tape and the leader block.
LOCK ERROR
Operator intervention required:
Trylocking or unlocking the magazine.
Tryanother magazine.
CheckACF mode.
Select correctACF mode.
For more information, see Chapter4. Automatic Cartridge Facility
(ACF) and Magazineon page 49.
LOCK MAGAZINE
Operator intervention required:
Lock the magazine by pressing the lock button on the left side of the
front of theACF.
Chapter3. Drive Operator Panel and Controls 25