Heatsink Clip Load Methodology
CHeatsink Clip Load Methodology
C.1 Overview
This section describes a procedure for measuring the load applied by the heatsink/clip/ fastener assembly on a processor package.
This procedure is recommended to verify the preload is within the design target range for a design, and in different situations. For example:
•Heatsink preload for the LGA771 socket.
•Quantify preload degradation under bake conditions.
Note: This document reflects the current metrology used by Intel. Intel is continuously exploring new ways to improve metrology. Updates will be provided later as this document is revised as appropriate.
C.2 Test Preparation
C.2.1 Heatsink Preparation
Three load cells are assembled into the base of the heatsink under test, in the area interfacing with the processor Integrated Heat Spreader (IHS), using load cells equivalent to those listed in Section C.2.2.
To install the load cells, machine a pocket in the heatsink base, as shown in Figure
The depth of the pocket depends on the height of the load cell used for the test. It is necessary that the load cells protrude out of the heatsink base. However, this protrusion should be kept minimal, as it will create an additional load offset since the heatsink base is artificially raised. The measurement load offset depends on the whole assembly stiffness (i.e. motherboard, clip, fastener, etc.). For example, the
Note: When optimizing the heatsink pocket depth, the variation of the load cell height should also be taken into account to make sure that all load cells protrude equally from the heatsink base. It may be useful to screen the load cells prior to installation to minimize variation.
83 |