Thermal/Mechanical Reference Design
2Thermal/Mechanical Reference Design
This chapter describes the thermal/mechanical reference design for
2.1Mechanical Requirements
The mechanical performance of the processor cooling solution must satisfy the requirements described in this section.
2.1.1Processor Mechanical Parameters
Table 2-1. Processor Mechanical Parameters Table
Parameter | Minimum | Maximum | Unit | Notes |
|
|
|
|
|
Volumetric Requirements and Keepouts |
|
|
| 1 |
|
|
|
|
|
Static Compressive Load |
|
|
| 3 |
|
|
|
|
|
Static Board Deflection |
|
|
| 3 |
|
|
|
|
|
Dynamic Compressive Load |
|
|
| 3 |
|
|
|
|
|
Transient Bend |
|
|
| 3 |
|
|
|
|
|
Shear Load |
| 70 | lbf | 2,4,5 |
|
| 311 | N |
|
|
|
|
|
|
Tensile Load |
| 25 | lbf | 2,4,6 |
|
| 111 | N |
|
|
|
|
|
|
Torsion Load |
| 35 | in*lbf | 2,4,7 |
|
| 3.95 | N*m |
|
|
|
|
|
|
Notes:
1.Refer to drawings in Appendix B.
2.In the case of a discrepancy, the most recent
3.These socket limits are defined in the LGA771 Socket Mechanical Design Guide.
4.These package handling limits are defined in the
5.Shear load that can be applied to the package IHS.
6.Tensile load that can be applied to the package IHS.
7.Torque that can be applied to the package IHS.
13 |