Heatsink Clip Load Methodology

Alternate Heatsink Sample Preparation

As just mentioned, making sure that the load cells have minimum protrusion out of the heatsink base is paramount to meaningful results. An alternate method to make sure that the test setup will measure loads representative of the non-modified design is:

Machine the pocket in the heatsink base to a depth such that the tips of the load cells are just flush with the heatsink base.

Then machine back the heatsink base by around 0.25 mm [0.01”], so that the load cell tips protrude beyond the base.

Proceeding this way, the original stack height of the heatsink assembly should be preserved. This should not affect the stiffness of the heatsink significantly.

Figure C-1. Load Cell Installation in Machined Heatsink Base Pocket - Bottom View

Heatsink Base

 

Pocket

Package IHS

Diameter ~

Outline (Top

29 mm

Surface)

[~1.15”]

 

 

Load

 

Cells

84

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

Page 84
Image 84