  | Introduction  | 
Table  | 
  | |
  | 
  | 
  | 
  | Document | Comment  | 
  | 
  | 
  | 
  | Available electronically  | |
  | CEK Thermal Models (in Flotherm* and Icepak*)  | 
  | 
  | 
  | 
  | 
  | Available electronically  | |
  | Models (in Flotherm and Icepak)  | 
  | 
  | 
  | 
  | 
  | RS - Wolfdale Processor Family BIOS Writers Guide (BWG)  | See Note following table.  | 
  | 
  | 
  | 
  | Thin Electronics Bay Specification (A Server System Infrastructure (SSI)  | www.ssiforum.com  | 
  | Specification for Rack Optimized Servers  | 
  | 
  | 
  | 
  | 
Note: Contact your Intel field sales representative for the latest revision and order number of this document.
1.4Definition of Terms
Table   | Terms and Descriptions (Sheet 1 of 2) | |
  | 
  | 
  | 
  | Term | Description | 
  | 
  | 
  | 
  | Bypass  | Bypass is the area between a passive heatsink and any object that can act to form a  | 
  | 
  | duct. For this example, it can be expressed as a dimension away from the outside  | 
  | 
  | dimension of the fins to the nearest surface.  | 
  | 
  | 
  | 
  | DTS | Digital Thermal Sensor replaces the Tdiode in previous products and uses the same  | 
  | 
  | sensor as the PROCHOT# sensor to indicate the   | 
  | 
  | value represents the number of degrees below the TCC activation temperature.  | 
  | 
  | 
  | 
  | MSR | The processor provides a variety of model specific registers that are used to control and  | 
  | 
  | report on processor performance. Virtually all MSRs handle system related functions and  | 
  | 
  | are not accessible to an application program.  | 
  | 
  | 
  | 
  | FMB | Flexible Motherboard Guideline: an estimate of the maximum value of a processor  | 
  | 
  | specification over certain time periods. System designers should meet the FMB values to  | 
  | 
  | ensure their systems are compatible with future processor releases.  | 
  | 
  | 
  | 
  | FSC  | Fan Speed Control  | 
  | 
  | 
  | 
  | IHS | Integrated Heat Spreader: a component of the processor package used to enhance the  | 
  | 
  | thermal performance of the package. Component thermal solutions interface with the  | 
  | 
  | processor at the IHS surface.  | 
  | 
  | 
  | 
  | LGA771 Socket  | The   | 
  | 
  | through this surface mount, 771 Land socket. See the LGA771 Socket Mechanical  | 
  | 
  | Design Guide for details regarding this socket.  | 
  | 
  | 
  | 
  | PMAX  | The maximum power dissipated by a semiconductor component.  | 
  | PECI | A proprietary   | 
  | 
  | Intel processor and chipset components to external thermal monitoring devices, for use  | 
  | 
  | in fan speed control. PECI communicates readings from the processors Digital Thermal  | 
  | 
  | Sensor. PECI replaces the thermal diode available in previous processors.  | 
  | 
  | 
  | 
  | ΨCA  | |
  | 
  | solution performance using total package power. Defined as (TCASE – TLA) / Total  | 
  | 
  | Package Power. Heat source should always be specified for Ψ measurements.  | 
  | 
  | 
  | 
  | ΨCS  | |
  | 
  | material performance using total package power. Defined as (TCASE – TS) / Total  | 
  | 
  | Package Power. | 
  | 
  | 
  | 
  | ΨSA  | |
  | 
  | performance using total package power. Defined as (TS – TLA) / Total Package Power.  | 
  | TCASE  | The case temperature of the processor, measured at the geometric center of the topside  | 
  | 
  | of the IHS.  | 
  | 
  | 
  | 
  | TCASE_MAX  | The maximum case temperature as specified in a component specification.  | 
  | TCC | Thermal Control Circuit: Thermal monitor uses the TCC to reduce the die temperature  | 
  | 
  | by using clock modulation and/or operating frequency and input voltage adjustment  | 
  | 
  | when the die temperature is very near its operating limits.  | 
  | 
  | 
  | 
10  | 
 |