Note: Make sure that all empty add-in card slots have filler panels installed.

9.Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22.

Removing and Installing the Processor Air Duct

Always operate your server system with the processor air duct in place. The air duct is required for proper airflow within the server system.

Removing the Processor Air Duct

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii.

2.Power down the server and unplug all peripheral devices and the AC power cable.

3.Remove the server system cover. For instructions, see “Removing the Server System Cover”.

4.Lift the processor air duct from its location behind the two fans.

AF002502

Figure 20. Removing the Processor Air Duct

28

Intel® Server System SR1520ML User’s Guide

Page 48
Image 48
Intel SR1520ML manual Removing and Installing the Processor Air Duct, Removing the Processor Air Duct