
Chapter 2 — Configuring the CK30
All configuration responses are routed with the
$NGCFGRSP transaction ID. The DCS 30X or Intermec Gateway cannot keep track of multiple applications sending reader or configuration commands. If you have two host applications sending reader or configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all CK30s.
To set up the host computer
•Verify that the host computer can communicate with the DCS 30X or Intermec Gateway.
To set up the application
•Prepare and write a host application that can communicate with the DCS 30X or Intermec Gateway and send transactions to and receive transactions from the CK30 in this format:
transaction header
TMF field
commands
where:
transaction is a
header number, date and time, source application ID, destinations application ID, transaction ID, and other information. You must set the system message (SYS$MSG) flag to E in the transaction header. For help, see the DCS 30X or Intermec Gateway user’s manual.
36 | CK30 Handheld Computer User’s Manual |