Juniper Networks M160 Maintaining Host Module Components, User@host show chassis routing-engine

Models: M160

1 312
Download 312 pages 48.69 Kb
Page 155
Image 155

Maintaining Hardware Components

For further description of the output from the command, see the JUNOS Internet Software Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management.

Maintaining Host Module Components

The router can have a Routing Engine in each of the slots labeled RE 0 and RE 1 and a Miscellaneous Control Subsystem (MCS) in each of the slots labeled MCS 0 and MCS 1 at the rear of the chassis, as shown in Figure 3. Each paired Routing Engine and MCS function together as a host module. To maintain the host module, perform the following procedures regularly:

Check the LCD and the host module LEDs on the craft interface. The LCD reports host module status during normal operation and describes the cause of failures when they occur. The green LEDs labeled ONLINE and MASTER light steadily for the master host module when it is functioning normally. The ONLINE LED also lights for the standby host module if it is installed. For more information about the LEDs and LCD, see Craft Interface on page 27.

Issue the CLI show chassis routing-enginecommand to check the status of the Routing Engines. As shown in the sample output, the master Routing Engine is designated Master in the Current state field:

user@host> show chassis routing-engine

 

 

Routing Engine status:

 

 

 

 

Slot 0:

 

 

 

 

Current state

 

Master

 

 

Election priority

 

Master (default)

 

Temperature

37

degrees C / 98 degrees F

DRAM

768

MB

 

 

Memory utilization

18

percent

 

 

CPU utilization:

 

 

 

 

User

0

percent

 

 

Background

0

percent

 

 

Kernel

2

percent

 

 

Interrupt

0

percent

 

 

Idle

98

percent

 

 

Model

 

RE-2.0

 

 

Serial ID

 

8b00000792898b01

 

Start time

 

2003-04-29 16:09:49 PDT

Uptime

 

16 days, 3 hours, 6 minutes, 34 seconds

Load averages:

 

1 minute

5 minute

15 minute

 

 

0.00

0.00

0.00

Routing Engine status:

 

 

 

 

Slot 1:

 

 

 

 

Current state

 

Backup

 

 

Election priority

 

Backup (default)

 

Temperature

36

degrees C / 96 degrees F

DRAM

768

MB

 

 

Memory utilization

16

percent

 

 

CPU utilization:

 

 

 

 

User

0

percent

 

 

Maintaining Host Module Components

 

131

 

Page 155
Image 155
Juniper Networks M160 manual Maintaining Host Module Components, User@host show chassis routing-engine