M160 Internet Router Hardware Guide
State Online - Master clock
Temperature 40 degrees C / 104 degrees F
Frequency:
Setting 125.00 MHz
Measurement 125.01 MHz
Power:
3.3 V 3274 mV
5.0 V bias 4974 mV
8.0 V bias 8183 mV
BUS Revision 12
PCG 1 status:
State Online - Standby
Temperature 40 degrees C / 104 degrees F
Frequency:
Setting 125.00 MHz
Measurement 125.03 MHz
Power:
3.3 V 3267 mV
5.0 V bias 4993 mV
8.0 V bias 8190 mV
BUS Revision 12
For furtherdescription of the output from the command, see the JUNOS
Internet SoftwareOperational Mode Command Reference: Protocols,Class of
Service, Chassis, and Management.
Maintaining SFMs
The router can have a Switchingand Forwarding Module (SFM) in each of the slots
labeled SFM 0 through SFM 3 at the rear of the chassis, as shownin Figure 3.
To maintain the SFMs, perform the following procedures regularly:
Check the LEDs on the SFM faceplates. The green LED lab eled OKlight s
steadily when an SFM is functioning normally. Formore information, see
“SFM Components” on page 20.
Issue the CLI show chassis sfm command to check the status ofthe SFMs. The
following sample output is for a router with four SFMs installed:
user@host> show chassis sfm
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 41 3 0 64 19 46
1 Online 42 5 0 64 19 46
2 Online 43 4 0 64 19 46
3 Online 41 3 0 64 19 46
For more detailedoutput, add the detail option. The following examplealso
specifies a slot number (1), which is optional:
user@host> show chassis sfm detail 1
136 Maintaining Packet ForwardingEng ine Components