11.Reinstall the rear lower impeller by sliding it back into the chassis and tightening the thumbscrew at each corner of the impeller cover. For complete instructions, see “Installing the Rear Lower Impeller Assembly” on page 155.

12.Order new fuses from an electrical supply house to replace the spares in the J244 group. The Cooper Bussman product number for each fuse is GMT- X , where X is the amperage rating. For example, product number GMT-15is

a 15-A fuse, required for an FPC.

Figure 106: Fuse Locations in the Fuse Box

J243

J242

J244

J241

A B C D A B C D A B C D A B C D

MCS0 12A SFM0 10A FPC7 15A FPC6 15A

FPC5 15A SFM1 10A MCS1 12A SFM3 10A

SPARE 1A SPARE 10A SPARE 12A SPARE 15A

SFM2 10A FPC4 15A PCG1 1A FPC3 15A

J240

FPC2 15A A

FPC1 15A B

FPC0 15A C

PCG0 1A D

1238

Table 25: Fuse Specifications

Indicator Bulb

 

 

 

 

 

Color

Component

Fuse Rating

Quantity

Locations

 

 

 

 

 

Red and blue

FPC

15 A

9

J240 A, B, and C

 

 

 

 

J241 B and D

 

 

 

 

J242

A

 

 

 

 

J243

C and D

 

 

 

 

J244

D (spare)

 

 

 

 

 

Yellow and green

MCS

12 A

3

J242 C

 

 

 

 

J243

A

 

 

 

 

J244

C (spare)

 

 

 

 

 

Red and white

SFM

10 A

5

J241 A

 

 

 

 

J242

B and D

 

 

 

 

J243

B

 

 

 

 

J244

B (spare)

 

 

 

 

 

Gray

PCG

1 A

3

J240 D

 

 

 

 

J241 C

 

 

 

 

J244

A (spare)

 

 

 

 

 

 