M160 Internet Router Hardware Guide

Component LCD Message CLIMessage

Temperature Warm YELLOW ALARM - Temperature Warm
Temperature Hot RED ALARM - Temperature Hot
Temperature
sensors
Sensor Failure RED ALARM - Temperature sensor failure
PEM pem-ID Removed YELLOW ALARM - PEM pem-ID Removed
PEM pem-ID High
Temp
RED ALARM - PEM pem-ID High Temperature
PEM pem-IDOutput Fail REDALARM - PEM pem-ID Output Failure
Power supplies
PEM pem-ID Input Fail RED ALARM - PEM pem-ID Input Failure
SFM sfm-number
Failure
RED ALARM - SFMsfm-number Failure(displayed
only if no alternate SFM is housed in chassis)
SFMs
SFM sfm-number
Removed
RED ALARM - SFM sfm-number
Removed(displayed only if no alternate
SFM is housed in chassis)
Host host-number
Failure
RED ALARM - Host host-number Failure
Host modules
Host host-number
Removed
RED ALARM - Host host-number Removed
Craft interface CraftFailure YELLOW ALARM - Craft Failure

Table 27: SONET/SDH Interface Alar mMe ssages

LCD Message CLI Message

interface-name so-x/x/xBERR-SD interface-name so-x/x/x- SONET bit error rate defect
interface-name so-x/x/xBERR-SF interface-name so-x/x/x- SONET bit e rror rate fault
interface-name so-x/x/xLAIS interface-name so-x/x/x- SONET line AIS
interface-name so-x/x/xLOF interface-name so-x/x/x- SONET loss of frame
interface-name so-x/x/xLOL interface-name so-x/x/x- SONET los s of light
interface-name so-x/x/xLOP interface-name so-x/x/x- SONET loss ofpointer
interface-name so-x/x/xLOS interface-name so-x/x/x- SONET loss of signal
interface-name so-x/x/xLRDI interface-name so-x/x/x- SONET line r emote defect
indicator
interface-name so-x/x/xPAI S interface-name so-x/x/x- SONET path AIS
interface-name so-x/x/xPL L interface-name so-x/x/x- SONET PLL lock
interface-name so-x/x/xPMIS interface-name so-x/x/x- SONET path mismatch
interface-name so-x/x/xPRDI interface-name so-x/x/x- SONET pathremote defect
indicator
interface-name so-x/x/xREI interface-name so-x/x/x- S ONET remote error
indicator
210 Overview of Troubleshooting Resources