Juniper Networks M160 manual Removing the Rear Upper Impeller Assembly

Models: M160

1 312
Download 312 pages 48.69 Kb
Page 181
Image 181

Replacing Hardware Components

Removing the Rear Upper Impeller Assembly

To remove the rear upper impeller assembly, follow this procedure (see Figure 77 and Figure 78, which show the two types of impeller that can be installed):

1.Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. Make sure the router is attached to a proper earth ground. For more information about ESD, see “Preventing Electrostatic Discharge Damage” on page 226.

2.Loosen the thumbscrew at each corner of the impeller cover, using a Phillips screwdriver if necessary.

3.Grasp the thumbscrews at opposite corners of the impeller cover and slide the assembly halfway out of the chassis.

CAUTION: To avoid injury, as you slide the assembly out of the chassis do not touch any part of the impeller behind the front panel—the impeller might still be spinning.

4.When the impeller is no longer spinning, slide the assembly completely out of the chassis.

Figure 77: Removing the Rear Upper Impeller Assembly

1211

Replacing Cooling System Components

 

157

 

Page 181
Image 181
Juniper Networks M160 manual Removing the Rear Upper Impeller Assembly