Juniper Networks M160 manual Maintaining Packet Forwarding Engine Components

Models: M160

1 312
Download 312 pages 48.69 Kb
Page 156
Image 156

M160 Internet Router Hardware Guide

Background

0

percent

Kernel

0

percent

Interrupt

0

percent

Idle

100

percent

Model

 

RE-2.0

Serial ID

 

6d000007c8150801

Start time

 

2003-04-22 10:01:29 PDT

Uptime

 

16 days, 3 hours, 6 minutes, 34 seconds

Issue the CLI show chassis environment mcs command to check the status of the MCSs. As shown in the sample output, the MCS that belongs to the master host module is designated Master in the State field:

user@host> show chassis environment mcs

MCS 0 status:

 

 

State

 

 

Online Master

Temperature

48

degrees C / 118 degrees F

Power:

 

 

 

3.3

V

3299

mV

5.0

V

4971

mV

12.0 V

11770

mV

5.0

V bias

4989

mV

8.0

V bias

8246

mV

BUS Revision

12

 

FPGA Revision

13

 

MCS 1 status:

 

 

State

 

 

Online Standby

Temperature

51 degrees C / 123 degrees F

Power:

 

 

 

3.3V

 

3316

mV

5.0

V

5001

mV

12.0 V

11775

mV

5.0

V bias

5001

mV

8.0

V bias

8249

mV

BUS Revision

12

 

FPGA Revision

13

 

For further description of the output from the commands, see the JUNOS Internet Software Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management.

Maintaining Packet Forwarding Engine Components

For instructions on maintaining Packet Forwarding Engine components, see the following sections:

Maintaining FPCs on page 133

Maintaining PICs and PIC Cables on page 134

Maintaining the PCGs on page 135

132 Maintaining Packet Forwarding Engine Components