M160 Internet Router Hardware Guide
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
Model RE-2.0
Serial ID 6d000007c8150801
Start time 2003-04-22 10:01:29 PDT
Uptime 16 days, 3 hours, 6 minutes, 34 seconds
Issue the CLI show chassis environment mcs command to check the status of the
MCSs. As shown in the sample output, th e MCS that belongs to the master
host module is designated Master in the State field:
user@host> show chassis environment mcs
MCS 0 status:
State Online Master
Temperature 48 degrees C / 118 degrees F
Power:
3.3 V 3299 mV
5.0 V 4971 mV
12.0 V 11770 mV
5.0 V bias 4989 mV
8.0 V bias 8246 mV
BUS Revision 12
FPGA Revision 13
MCS 1 status:
State Online Standby
Temperature 51 degrees C / 123 degrees F
Power:
3.3V 3316 mV
5.0 V 5001 mV
12.0 V 11775 mV
5.0 V bias 5001 mV
8.0 V bias 8249 mV
BUS Revision 12
FPGA Revision 13
For further description of the output from the commands, see the JUNOS
Internet Software Operational Mode Comman d Reference: Protocols, Class
of Service, Chassis, and Management.
Maintaining Packet Forwarding Engine Components
For instructions onmaintaining Packet Forwarding Engine components,see the
following sections:
Maintaining FPCs on page 133
Maintaining PICs and PIC Cables on page 134
Maintaining the PCGs on page 135
132 Maintaining Packet ForwardingEng ine Components