Calibration
Printing a Calibration Target
You print the calibration target using a defined set of printer response curves as the starting point. Most often the starting point is the ending point of the previous calibration event. Options for other starting points exist for special needs.
When you print a calibration target, a specific calibration event number is created that is related to the media and printer. Each target is numbered as it is printed so that you can refer to the number when it is requested.
Before you print the calibration target, check the following:
✔Is the correct type of media (glossy or matte) loaded in the printer?
✔In the Configuration application, is the selected XtraLife ribbon type the same as that loaded in the printer (see page 30)?
To print a calibration target:
1.From the Calibration menu select Print Calibration Target.
2.In the Select Media dialog box, select the media to calibrate, then click Next.
3.In the Select Calibration Starting Point dialog box, select a starting point (see page 78), then click Next.