Calibration
1.From the Calibration menu select Analyze Calibration Target.
2.Enter the event number from the target or scan the bar code.
NOTE: If the event has been completed
(see page 92), a warning message appears.
3.Click Next to print the calibration target.
4.Analyze the target. You can only use Status A densitometers (see page 92).
✔For visual analysis
a.Visually examine the calibration print and enter the cluster number that appears most neutral (gray).
b.Click Next.
✔For analysis on a patch reading densitometer
a.Click Next. The Measure Target Densities dialog box appears.
b.Read the RGB values for each target step. The values appear in the dialog box. If necessary, use the cursor to adjust the sequence of the readings, positioning the highlight row to reread a patch.
c.Click Done.