Installing the system

You can update your TRITON STUDIO system to Version

2.0via the internal floppy drive, by loading TRITON STU- DIO Version 2.0 operating system files from DOS-formatted floppy disks.

If you are using a system is earlier than version 2.0.0, follow the procedure described below to install the “TRITON STU- DIO Operating System Version 2.0” system files (five 2HD MS-DOS format floppy disks) into your TRITON STUDIO.

*The system software version is shown in the lower right of the LCD screen when you turn on the power.

To obtain the “TRITON STUDIO Operating System Version 2.0” system files, please contact your local Korg distributor. You may also download the files from the Korg website (http://www.korg.com/downloads). Updating to Version

2.0requires five floppy disks. When creating disks from the downloaded files, be sure to copy only the contents of the downloaded folders to the disks, and not the folders them- selves.

When you update the system, all data in the internal memory will be initialized. If the internal memory con- tains any data you want to keep, use “Save All” or “Save PCG” to save your data before you update the system. (BG p.60, PG p.166)

Updating the TRITON STUDIO operating system

You will need five 2HD MS-DOS format floppy disks con- taining the “TRITON STUDIO Operating System Version 2.0” files.

1While holding down the TRITON STUDIO’s [ENTER] key and [LOCATE] key, turn on the power.

2The LCD screen will indicate “Please insert System 1 disk.” Insert the “O.S. Version 2.0 - Disk #1” disk into the floppy disk drive.

3The system will automatically begin loading, and the LCD screen will show the following messages.

“Now loading...” “Now erasing ROM”

“Checking the system’s check sum”

4The display will indicate “Please change to System 2 disk.” Remove disk 1 and insert “O.S. Version 2.0 - Disk #2” disk.

5The same messages as in step 3 will be displayed, and then the display will indicate “Please change to System 3 disk.” Remove disk 2 and insert “O.S. Version 2.0 - Disk #3.”

Repeat this until “O.S. Version 2.0 - Disk #5.”

6After loading the final disk, the following messages will appear in the LCD screen:

“Checking system’s check sum” “System load was completed”

After the update has been successfully completed, the TRITON STUDIO will re-start using the new operating system.

If a disk error occurs during this process, remove the disk and turn off the power. Then try the update pro- cess once again, starting from step 1.

While the system is being updated, do not touch any switches or controls on the TRITON STUDIO and never turn off the power.

Introduction

3

Page 8
Image 8
Korg V2 manual Installing the system, Updating the Triton Studio operating system