4.Press ↓ to select CALIBRATE and press ENT. The Device Calibration menu will appear.
5.Highlight NUM PTS, press ENT and select 3. Press ENT.
6.Make sure your tank is empty, then highlight FLUID LEVEL and press
ENT. Select EMPTY LEVEL and press ENT.
7.Select CALIBRATE and press ENT. The following message will appear: Empty Level Calibration Completed. Press ENTER.
8.Add half a tank of fuel, highlight FLUID LEVEL and press ENT. Select
HALF LEVEL and press ENT.
9.Select CALIBRATE and press ENT. The following message will appear: Half Level Calibration Completed. Press ENT.
10.Fill up the tank, then highlight FLUID LEVEL and press ENT. Select
FULL LEVEL and press ENT.
11.Highlight CALIBRATE and press ENT. The following message will ap- pear: Full Level Calibration Completed. Press ENT, then press EXIT re- peatedly to get back to the main display.
Num Pts menu with
Fluid Level menu (center). Calibration Done window (right).
In a