GS700TS Smart Switch Software Administration Manual

2.Enter the Recipients IP address in the provided field in the first row.

3.Select either Traps or Informs in the Notification Type provided field in the first row.

4.Enter the User Name in the provided field in the first row.

5.Select the Security Level from the list in the provided field in the first row.

6.Enter the UDP Port in the provided field in the first row.

7.Select the Filter Name from the list in the provided field in the first row.

8.Enter the Timeout and Retries in the provided fields in the first row.

9.Click ADD to update the device.

To remove a trap:

1.Click System > SNMP > SNMPv3 > Trap Configuration. The SNMPv3 Trap Configuration screen displays.

2.Select the trap entry.

3.Click DELETE to remove the entry.

Trap Filter Name

The SNMPv3 Trap Filter Name screen permits creating filtering names based on OIDs. Each OID is linked to a device feature or a portion of a feature. The SNMPv3 Trap Filter Name screen also allows network managers to filter notifications.

To define the SNMPv3 Trap Filter Name:

1.Click System > SNMP > SNMPv3 > Trap Filter Name. The SNMPv3 Trap Filter Name screen displays:

3-35

Managing System Settings

v1.0, June 2009

Page 70
Image 70
NETGEAR GS748TS manual Trap Filter Name