Chapter 7 Using the BCM Fault Management System 161
BCM50 Administration Guide
25 63 critical Core
Telephony
Core Telephony -
No DTMF receivers
available.
If this happens more
than once in a 5
minute span check
that any auto answer
or DISA configured
trunks are operating
properly. If they are
not operating
properly reboot the
system and contact
your local support
group.
Yes Yes Yes Yes
26 67 critical Core
Telephony
Core Telephony -
Invalid trunk media
bay module
connected to an
expansion chassis.
Power down the
system and check all
connections to the
expansion chassis
containing the digital
or analog trunk
module. Check that
the hardware being
used is supported in
the market your
have selected in
Core Telephony. If
the problem persists,
replace the module.
Yes Yes Yes Yes
27 68 critical Core
Telephony
Core Telephony -
Unsupported set/
peripheral
connected.
Disconnect the set/
peripheral from the
port and reconnect it
to a valid port. If the
problem persists
replace the set/
peripheral.
Yes Yes Yes Yes
28 69 critical Core
Telephony
Core Telephony -
General software
error.
Reboot system and
contact your local
support group.
Yes Yes Yes Yes
29 71 warning Core
Telephony
Core Telephony -
Emergency transfer
relay activated
indicating a power
issue or Core
Telephony down
condition.
No Action Required. Yes No No No
30 72 critical Core
Telephony
Core Telephony -
TEI request on
ISDN device on
system.
Disconnect all
station side ISDN
devices. If problem
persists contact your
local support group.
Yes Yes Yes Yes
31 75 critical Core
Telephony
Core Telephony -
Digital trunking
clock in free run.
Check your cabling
from any DTM
modules to the
external network.
Get your network
provider to check the
circuit.
Yes Yes Yes Yes
32 77 critical Core
Telephony
Core Telephony -
Persistent Data
Repository
corruption.
Perform a restore
with a known good
backup. If problem
persists contact your
local support group.
Yes Yes Yes Yes