190 Chapter 7 Using the BCM Fault Management System
NN40020-600NN40020-600
268 11004 Information Platform
Status
Monitor
Platform Status
Monitor - Memory
recovered.
No Action Required.
Recovery alarm for
corresponding alarm
11202
Yes No No No
269 11005 Information Platform
Status
Monitor
Platform Status
Monitor - CPU load
recovered.
No Action Required.
Recovery alarm for
corresponding alarm
11203.
Yes No No No
270 11006 Information Platform
Status
Monitor
Platform Status
Monitor - LAN
recovered.
No Action Required.
Recovery alarm for
corresponding alarm
11204.
Yes No No No
271 11011 Information Platform
Status
Monitor
Platform Status
Monitor - Local
Temperature
recovered.
No Action Required.
Recovery alarm for
corresponding
alarms 11209 and
11405.
Yes No No No
272 11012 Information Platform
Status
Monitor
Platform Status
Monitor - Remote
Temperature
recovered.
No Action Required.
Recovery alarm for
corresponding
alarms 11210 and
11406.
Yes No No No
273 11014 Information Platform
Status
Monitor
Platform Status
Monitor - Fan
recovered.
No Action Required.
Recovery alarm for
corresponding
alarms 11212 and
11408.
Yes No No No
274 11015 Information Platform
Status
Monitor
Platform Status
Monitor - Router
recovered.
No Action Required.
Recovery alarm for
corresponding alarm
11409.
Yes No No No
275 11016 Information Platform
Status
Monitor
Platform Status
Monitor - OAM Port
Link Up.
No Action Required.
Recovery alarm for
corresponding alarm
11214.
Yes No No No
276 11017 Information Platform
Status
Monitor
Platform Status
Monitor - Customer
LAN Port 1 Link Up.
No Action Required.
Recovery alarm for
corresponding alarm
11215.
Yes No No No
277 11018 Information Platform
Status
Monitor
Platform Status
Monitor - Customer
LAN Port 2 Link Up.
No Action Required.
Recovery alarm for
corresponding alarm
11216.
Yes No No No
278 11019 Information Platform
Status
Monitor
Platform Status
Monitor - Customer
LAN Port 3 Link Up.
No Action Required.
Recovery alarm for
corresponding alarm
11217.
Yes No No No
279 11200 minor Platform
Status
Monitor
Platform Status
Monitor - failed to
read Power.
Reboot system and
if problem persists
contact your local
support group.
Yes No No No
280 11201 major Platform
Status
Monitor
Platform Status
Monitor - Hard drive
near capacity.
Contact local
support group for
assistance in
recovering drive
space.
Yes Yes Yes Yes
281 11202 major Platform
Status
Monitor
Platform Status
Monitor - Memory
near capacity.
Contact local
support group for
assistance in
analyzing memory
usage.
Yes Yes Yes Yes