Chapter 7 Using the BCM Fault Management System 163
BCM50 Administration Guide
41 270 minor Core
Telephony
Core Telephony -
Set initialization
error from an invalid
message from the
set.
If the event occurs
more than once in a
5 minute span then
disconnect the set in
question. If problem
stops replace set
and check cable
between set and
system.
Yes No No No
42 271 minor Core
Telephony
Core Telephony - A
set is trying to
initialize that has
incompatible
firmware on the
system.
Verify that all types
of attached sets/
peripherals initialize
and function. If
something is not
working reset it. If
the problem persists
contact your local
support group.
Yes No No No
43 323 minor Core
Telephony
Core Telephony -
"Degraded Minute"
short term alarm
threshold has been
exceeded on the
DTM. The module is
in a no-new-calls
state.
Check your cabling
from any DTM
modules to the
external network and
run loopback tests
on the circuit to
check for network
issues. If long term
alarms occur get
your network
provider to check the
circuit during
problem conditions.
Yes No No No
44 324 minor Core
Telephony
Core Telephony -
"Severely Errored
Second" short term
alarm threshold has
been exceeded on
the DTM. The
module is in a no-
new-calls state.
Check your cabling
from any DTM
modules to the
external network and
run loopback tests
on the circuit to
check for network
issues. If long term
alarms occur get
your network
provider to check the
circuit during
problem conditions.
Yes No No No
45 325 minor Core
Telephony
Core Telephony -
"Errored Second"
short term alarm
threshold has been
exceeded on the
DTM. The module is
in a no-new-calls
state.
Check your cabling
from any DTM
modules to the
external network and
run loopback tests
on the circuit to
check for network
issues. If long term
alarms occur get
your network
provider to check the
circuit during
problem conditions.
Yes No No No