Appendix A Management Information Bases 347
BCM50 Administration Guide
Small Site Event MIB
The Small Site Events MIB defines events (SNMP traps) that can be used by any Small Site
product or component. BCM50 traps can be captured and viewed using a standard SNMP fault
monitoring framework or trap watcher.
SNMP traps are generated by the BCM50 if you have enabled SNMP for specific BCM50 alarms.
You configure SNMP settings using the Alarm Settings task in the Element Manager. For
information about how to configure SNMP traps, see Chapter 6, “Managing BCM50 with SNMP,”
on page 133.
Table 109 lists the BCM50-specific SNMP trap fields for Small Site Event MIBs.
Table 110 lists the BCM50-specific SNMP variable bindings.
Table 109 BCM50-specific SNMP trap fields for the Small Site Event MIB
Trap Field Description
Enterprise OID identifies the product
(iso.org.dod.internet.private.enterprises.nortel.smallsite.common.events[1.3.
6.1.4.1.562.37.3.1])
Agent address IP address of one of the BCM50 interfaces
Generic trap type 6 for Enterprise-specific traps
Specific trap type 1 = eventInfo trap type
2 = eventWarning trap type
3 = eventError trap type
Time stamp the system up time
Table 110 BCM50-specific variable bindings
Trap Field Description
Binding #1 Contains the corresponding alarm ID.
OID: 1.3.6.1.4.1.562.37.3.1.1.0
Binding #2 Contains the name of the software component that generated the alarm
(trap). This is in the 3-part DN format defined in the Nortel Common Alarm
Framework. The 3-part DN is in the format:
systemId=BCM, entityId=System Name, subEntityId=Component Name
OID: 1.3.6.1.4.1.562.37.3.1.2.0
Binding #3 Contains the alarm (trap) Date and Time
OID: 1.3.6.1.4.1.562.37.3.1.3.0
Binding #4 Contains the alarm (trap) problem description
OID: 1.3.6.1.4.1.562.37.3.1.4.0