Chapter 7 Using the BCM Fault Management System 195
BCM50 Administration Guide
335 12036 warning Backup and
Restore
Backup and Restore
- Backup file is not
recognizable.
Use a different
backup file and if
problem persists
contact your local
support group
Yes No No No
336 12037 minor Backup and
Restore
Backup and Restore
- Internal error.
Attempt another
backup or restore
and if problem
perists contact your
local support group
Yes No No No
337 12038 minor Backup and
Restore
Backup and Restore
- A backup file does
not exist.
Attempt another
backup or restore
and if problem
perists contact your
local support group
Yes No No No
338 12041 minor Backup and
Restore
Backup and Restore
- Internal error.
Attempt another
backup or restore
and if problem
perists contact your
local support group
Yes No No No
356 12059 major Backup and
Restore
Backup and Restore
- The Voice
Application Interface
Service(ctiserver)
service could not be
restarted after a
restore.
Restart the system
and attempt another
restore. If problem
persists contact your
local support group.
Yes Yes Yes N/A
357 12202 Information Backup and
Restore
Backup and Restore
- Onbox Backup/Log
collection has
completed.
No Action Required. Yes No No No
358 12203 Information Backup and
Restore
Backup and Restore
- Backup/Log files
have been
successfully
transferred off box.
No Action Required. Yes No No No
359 12204 Information Backup and
Restore
Backup and Restore
- Restore has
started.
No Action Required. Yes No No No
360 12205 Information Backup and
Restore
Backup and Restore
- Restore has
completed
successfully.
No Action Required. Yes No No No
361 12206 Information Backup and
Restore
Backup and Restore
- Restore has
rebooted the system
to complete its
operation.
No Action Required. Yes No No No
362 13002 Information UPS UPS - Power failure.Check local power
connected to the
system.
Yes No No No
363 13003 Information UPS UPS - Running on
UPS batteries.
Check local power
connected to the
system.
Yes No No No
364 13004 warning UPS UPS - Battery power
exhausted.
Check local power
connected to the
system.
Yes No No No
365 13005 warning UPS UPS - Reached run
time limit on
batteries.
Check local power
connected to the
system.
Yes No No No
366 13006 warning UPS UPS - Battery
charge below low
limit.
Check batteries in
UPS and replace if
needed.
Yes No No No