Error information page
When is displayed on the status information screen, click it to display the error details.
•Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
|
| OK: Normal operation |
|
| FAILED: Occurrence of trouble |
zWhen [FAILED] has appeared for an item | ||
| Parameter | Description |
| MAIN CPU BUS | Trouble has occurred in the microcomputer circuitry. Consult your dealer. |
| FAN | Trouble has occurred in the fan or its drive circuit. Consult your dealer. |
|
| The temperature inside the projector is high. It may be that the projector is being |
| OPTICS MODULE TEMPERATURE | used in an operating environment where the temperature is high such as near a |
|
| heating appliance. |
|
|
|
|
| The input air temperature is too high. It may be that the projector is being used in |
| INPUT AIR TEMPERATURE | an operating environment where the temperature is high such as near a heating |
|
| appliance. |
|
|
|
| OUTPUT AIR TEMPERATURE | The temperature around the lamp is too high. It may be that the projector’s |
| ventilation holes are blocked. | |
|
| |
|
|
|
| LAMP REMAIN TIME | The lamp runtime has exceeded the prescribed cumulative time, and it is now time |
| to replace the lamp. | |
|
| |
|
|
|
| LAMP STATUS | The lamp has failed to light. |
| Wait a short while for the lamp to cool off, and then turn on the power. | |
|
| |
|
|
|
| APERTURE | Trouble has occurred in the contrast shutter circuitry. Consult your dealer. |
| ||
|
| |
|
|
|
| SHUTTER | Trouble has occurred in the shutter circuitry. Consult your dealer. |
| ||
|
| |
|
|
|
|
| The air filter is blocked with dust. |
| DIRTY AIR FILTER | Turn off the MAIN POWER switch by following the procedure on page 37, and |
|
| then clean the air filter. (pp. |
| AIR FILTER CLEANER UNIT | The air filter unit is not installed. Install the air filter unit. |
| OPTICS MODULE TEMP.SENSOR | Trouble has occurred in the temperature detection sensor inside the projector. |
| Consult your dealer. | |
|
| |
| INPUT AIR TEMP.SENSOR | Trouble has occurred in the sensor used to detect the input air temperature. |
| Consult your dealer. | |
|
| |
| OUTPUT TEMP. SENSOR | Trouble has occurred in the sensor used to detect the exhaust air temperature. |
| Consult your dealer. | |
|
| |
| BATTERY | The backup battery has been run out. Consult your dealer. |
| CLOGGED FILTER SENSOR | Problem with clogged filter sensor. Consult your dealer. |
| AC POWER | AC power supply voltage input has dropped. Check that there is sufficient |
| electrical wiring capacity for the projector’s power consumption requirements. | |
|
| |
|
|
|
| LENS SHIFT | Problem with lens shift circuit. Consult your dealer. |
Special Features