5.5Cleaning Schedule

A clean printer operates efficiently. The following list of cleaning items and table below provides the recommended schedule and technique for cleaning the various parts of your printer safely and effectively.

∙Isopropyl alcohol

∙Cotton swabs

∙A clean, lint-free cloth

∙Soft-bristle brush

∙Soapy water/mild detergent

∙Compressed air

For your continued safety and to avoid damage, always turn ‘Off’ and unplug the printer before cleaning.

Isopropyl alcohol is a flammable liquid; always take proper CAUTION precautions when using this solvent.

Recommended Cleaning Schedule

 

Area

Method

Interval

 

 

Printhead

Using a cotton swab dampened with isopropyl

Clean after

 

 

 

alcohol, clean the printhead from end to end,

each roll or

 

 

 

removing all build-up. See Section 5.5.1.

box of labels,

 

 

 

 

 

or after each

 

 

 

WARNING! Before cleaning, allow the

 

 

 

 

 

roll of ribbon.

 

 

 

printhead to cool.

 

 

 

 

 

 

 

 

 

 

 

 

 

Platen

Using a cotton swab dampened with isopropyl

Clean after

 

 

Roller

alcohol, rotate the platen and remove all build-

each roll or

 

 

 

up. See Section 5.5.2.

box of labels,

 

 

 

 

 

or after each

 

 

 

 

 

roll of ribbon.

 

 

 

 

 

 

 

Media

Compressed air / soft-bristle brush and isopropyl

As needed,

 

 

Path / Tear

alcohol. Remove all build-up along the path that

based on a

 

 

Plate

the ribbon and paper follow through the printer.

weekly visual

 

 

 

 

 

inspection.

 

 

 

 

 

 

 

Media

Compressed air, isopropyl alcohol if needed.

Monthly or as

 

 

Sensor

Remove all build-up.

needed.

 

 

 

 

 

 

 

Interior

Soft-brush or compressed air. Remove all build-

As needed.

 

 

 

up. See Section 5.5.3.

 

 

 

 

 

 

 

 

Exterior

Mild detergent. Remove all build-up. See

As needed.

 

 

 

Section 5.5.3.

 

 

 

 

 

 

 

 

56

 

 

J693

 

Page 66
Image 66
Pitney Bowes J693 manual Recommended Cleaning Schedule Area Method Interval