Administration and Utilities
Polycom®, Inc. 509
Traps
Three types of traps are sent as follows:
ColdStart trap. This is a standard trap which is sent when the MCU is reset.
An Example of a ColdStart Trap
UltraSecureMode Boolean Indicates whether the RMX is operating in Ultra Secure Mode.
ChassisTemp Integer The temperature of the chasis.
NumPortsUsed Integer Number of ports currently in use.
NewCallsPerMinute Integer New calls in the last minute.
ScsfNewCallsPerMinute Integer Successful new calls in the last minute.
FldNewCallsPerMinute Integer Failed new calls in the last minute.
PctScsflNewCalls Integer Percentage of new calls in the last minute which were
successful.
CallsEndedScsflPerMin Integer Number of calls in the last minute which ended with a success
code.
CallsEndedFailedPerMin Integer Number of calls in the last minute which ended with a failure
code.
CallsEndedScsfl Integer Number of calls in the last minute which ended with a success
code.
CallsEndedFailed Integer Number of calls in the last minute which ended with a failure
code.
NumActvCnfrncs Integer Number of active conferences.
Unified MIB SNMP Fields (Continued)
Name Type Description
coldStart notification received from: 172.22.189.154 at 5/20/2007
7:03:12 PM
Time stamp: 0 days 00h:00m:00s.00th
Agent address: 172.22.189.154 Port: 32774 Transport: IP/UDP
Protocol: SNMPv2c Notification
Manager address: 172.22.172.34 Port: 162 Transport: IP/UDP
Community: public
Enterprise: enterprises.8072.3.2.10
Bindings (3)