Restoring Defaults and System Recovery
Polycom®, Inc. 872
6 Recommended: Click the Lan Configuration check box and modify the following parameters in
the utility’s dialog box using the information supplied by your network administrator.
Control Unit IP Address
Subnet Mask
Default Router IP Address
7Click OK.
8Remove the USB key from the PC.
9Insert the USB key in any USB port of the RealPresence Collaboration Server 800s.
10 Turn off the RealPresence Collaboration Server 800s, then turn it On.
11 Start the Collaboration Server Web Client application on the workstation.
aIn the browser’s address line, enter the IP address of the Control Unit in the following format:
http://<Control Unit IP Address>,
as defined in the USB key. If no Control Unit IP Address was defined, the IP address will be
192.168.1.254.
bClick Enter.
When the Collaboration Server Web Client Login window is displayed, the system was successfully
restored to factory defaults.
The restore to Factory Defaults removes the Management Network Service. If the above fields
addresses are not set, the Control Unit IP Address of the Management Network Service will be
192.168.1.254.