Printronix L1024 manual Fuser Temperature, Energy Timeout

Models: L1024

1 136
Download 136 pages 33.32 Kb
Page 64
Image 64

Fuser Temperature

The fuser temperature option allows you to reduce the normal temperature of the fuser by up to ±20 C in 5 degree increments. This reduction can be required due to the print media. For example, thinner material may curl or waffle at high temperatures and adhesive material on label material may melt. It is necessary to lower fuser temperature in such cases.

The selections on the control panel are:

Normal (this is the default selection)

±5 degrees C

±10 degrees C

±15 degrees C

±20 degrees C

Energy Timeout

The energy timeout option provides the ability to select the length of time before the printer goes into the energy saving mode. From the energy saving mode, the printer will require warm up time to bring the fuser to the configured temperature. Energy is saved by turning off heater power to the fuser.

The timeout selections are:

1 minutes

5 minutes (this is the default selection)

10minutes

30minutes

Disabled

3±20

Configuring the Printer

Page 64
Image 64
Printronix L1024 manual Fuser Temperature, Energy Timeout