Series 1 Delay

Values: 0+ msec, 15+ msec, 30+ msec

Specifies the delay between receiving the poll character and sending back the series 1 status. This delay is only approximate.

Series 1 Idle

Values: Enable or Disable.

When enabled, the printer will send the status approximately every 2 seconds. This status is sent if no data is being received and the buffer is empty.

RS±422 Input

Values: Enable or Disable.

Used to enable or disable the RS±422 serial input.