Series 1 Delay
Values: 0+ msec, 15+ msec, 30+ msec
Specifies the delay between receiving the poll character and sending back the series 1 status. This delay is only approximate.
Series 1 Idle
Values: Enable or Disable.
When enabled, the printer will send the status approximately every 2 seconds. This status is sent if no data is being received and the buffer is empty.
RS±422 Input
Values: Enable or Disable.
Used to enable or disable the RS±422 serial input.
Configuring the Printer | 3±43 |