Psion Teklogix 7530 G2 user manual UPC a, Upc E, Include Number Sys, Convert to UPC-A

Models: 7530 G2

1 296
Download 296 pages 42.88 Kb
Page 180
Image 180

Chapter 5: Configuration

Non-Decoded Scanners

Addendum

Important: Before “Addendum” can take effect, the “Short Code” parameter (see page 146) must be enabled.

Refer to “Addendum” on page 150.

Prefix/Suffix

See “Prefix/Suffix” beginning on page 151.

5.11.2.6 UPC A

Enabled

Set this parameter to on to enable “UPC A”.

Include Number Sys

If this parameter is enabled, the number system digit is included with the decoded bar code data.

Include Check

If this parameter is enabled, the check digit will be included with the decoded bar code data.

Addendum

Important: Before “Addendum” can take effect, the “Short Code” parameter (see page 146) must be enabled.

Refer to “Addendum” on page 150.

Prefix/Suffix

Refer to page 151 for details.

5.11.2.7 UPC E

Convert to UPC-A

Setting this parameter to on results in a non-standard decoding that returns 12 digits from the 6 digit UPC E bar code.