Chapter 5: Configuration

Decoded (Intermec ISCP)

5.11.4 Decoded (Intermec ISCP)

Tap on the Scanner dropdown menu, and choose Decoded (Intermec ISCP).

5.11.4.1 Decoded (Intermec) Options

Laser On Time

The value assigned to this parameter determines how long the imager will remain on when the scan button or trigger is pressed.

Double-tapping on this parameter displays a dialog box in which you can enter a value between 1 and 10 seconds.

5.11.4.2 Decoded (Intermec) Advanced Options

Continuous Scan Mode

Setting this parameter to on keeps the imager on and continuously decoding as long as the scanner button is pressed and held down.

Minimum Cancel Time

The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off.