Psion Teklogix 7530 G2 Enabled UPC-E1, UPC-E And UPC-E1 Check Digit, Conv. UPC-E To UPC-A

Models: 7530 G2

1 296
Download 296 pages 42.88 Kb
Page 193
Image 193

Chapter 5: Configuration

Decoded (Internal) Scanners

Prefix/Suffix

See “Prefix/Suffix” beginning on page 151.

5.11.3.10 UPC E

Enabled UPC-E

Set this parameter to on to allow “UPC E” bar code scans.

Enabled UPC-E1

Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans.

UPC-E And UPC-E1 Check Digit

If you enable one or both of these parameters, a check digit is included with the decoded bar code data.

UPC-E And UPC-E1 Preamble

When you double-tap on one of these parameters, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-E and UPC-E1 symbols transmitted to the host device: System Char – system character transmitted with the data, Country code and System Char – both the country code (“0” for USA) and system character are transmitted with the data or None – no preamble is transmitted. The lead-in characters are considered part of the symbol.

Conv. UPC-E To UPC-A

This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).

Conv. UPC-E1 To UPC-A

This parameter converts UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).