Psion Teklogix 7530 G2 user manual Interleaved 2

Models: 7530 G2

1 296
Download 296 pages 42.88 Kb
Page 210
Image 210

Chapter 5: Configuration

Decoded (Intermec ISCP)

Check Digit Verification

Uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. The available options are: One Check Digit or Two Check Digits.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Chars

Refer to page 148 for details.

5.11.4.13 Interleaved 2 of 5

Enabled

Set this parameter to on to enable “Interleaved 2 of 5”.

Reading Range

Determines the reading distance from which a bar code can be successfully scanned. The default setting Extended, allows for increased reading distance.

Check Digit Verification

Uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. The available options are: Disabled, MOD 10 Check, or French CIP.

Note: French CIP (French pharmaceutical) is only used with bar codes contain- ing 7 characters.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.