Psion Teklogix 7530 G2 user manual Bi-Direction Redundancy, Scanning Mode

Models: 7530 G2

1 296
Download 296 pages 42.88 Kb
Page 187
Image 187

Chapter 5: Configuration

Decoded (Internal) Scanners

“Linear security level 3” specifies that code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:

Code Type

Length

 

 

MSI Plessey

4 or less

D 2 of 5

8 or less

I 2 of 5

8 or less

“Linear security level 4” requires that all code types be successfully read three times before being decoded.

Bi-Direction Redundancy

Note: This parameter is only valid if a” Linear Security Level” is enabled.

When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.

5.11.3.3 Decoded (Internal) 2D Scanning Options (SE2223 only)

Scanning Mode

When you double-tap on this parameter, a dialog box is displayed in which you can choose one of the following scanning modes: Smart Raster, Always Raster, Programmable Raster, Slab Pattern, Cyclone Pattern or Semi-Omni Pattern.

Raster Height And Raster Expand Rate

These parameter determine the laser pattern’s height and rate of expansion.

Note: These parameters are only used when either Programmable Raster or Always Raster is assigned to the “2D Scanning Mode” parameter. “2D Raster Height” and “2D Raster Expand Rate” are intended for very specific applications and are usually not required for normal scanning purposes.

Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 15.

Psion Teklogix 7530 G2 Hand-Held Computer User Manual 159

Page 187
Image 187
Psion Teklogix 7530 G2 user manual Bi-Direction Redundancy, Scanning Mode, Raster Height And Raster Expand Rate