Chapter 5: Configuration

Non-Decoded Scanners

5.11.2.10 Code 11

Enabled

Set this parameter to on to enable “Code 11”.

Include Check

If “Include Check” is enabled, the check digit is included with the decoded bar code data.

Check Digits

This parameter can be set to None, One Check Digit or Two Check Digits.

Double-tap on this parameter to display a dialog box listing your options.

Highlight the check digit you want to use, and tap on OK.

If this parameter set to One Check Digit, it is assumed that the last digit is a check digit.

If this parameter is set to Two Check Digits, it is assumed that the last two digits are check digits.

Field Size/Chars

Refer to the description beginning on page 148 for details.

5.11.2.11 Interleaved 2 of 5

Enabled

Set this parameter to on to enable “Interleaved 2 of 5”.

Mod 10 Check

If this parameter is enabled, the “Mod 10” check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.

ITF Check

If this parameter is enabled, the ITF-14/16 Mod10 check digit is calculated.

Include Check

If this parameter is enabled, the check digit is included with the decoded bar code data.