Psion Teklogix 7530 G2 user manual Enable Trioptic Code, Convert To Code, Code 32 Prefix

Models: 7530 G2

1 296
Download 296 pages 42.88 Kb
Page 189
Image 189

Chapter 5: Configuration

Decoded (Internal) Scanners

5.11.3.5 Code 39

Enable

Setting this parameter to on enables “Code 39”.

Enable Trioptic Code 39

Note: “Trioptic Code 39” and “Full ASCII” should not be enabled simulta- neously. The scanner does not automatically discriminate between these two symbologies.

Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.

Convert To Code 32

Note: “Code 39” must be enabled in order for this parameter to function.

Setting this parameter to on allows the scanner to convert the bar code from “Code 39” to “Code 32”.

Code 32 Prefix

Note: “Convert to Code 32” must be enabled in order for this parameter to function.

When this parameter is enabled, the prefix character “A” is added to all “Code 32” bar codes.

Set Length L1 And Set Length L2

Lengths for “Code 39” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Psion Teklogix 7530 G2 Hand-Held Computer User Manual 161

Page 189
Image 189
Psion Teklogix 7530 G2 Enable Trioptic Code, Convert To Code, Code 32 Prefix, Set Length L1 And Set Length L2